Chrysalis Intelligence · Sponsors · Quidel Corporation

Quidel Corporation

San Diego, CA, US · 7 510(k) clearances · 10 recalls (1 Class I)

Total clearances
7
2021-11-23 → 2024-03-22
Last 12 months
0
Product codes
6
Most recent
2024-03-22
Trend

Clearance cadence by quarter

Portfolio

Product codes worked

Code Device name Class Specialty Clearances Most recent
QVF 2 2023-12-13
QYT Over-The-Counter Covid-19 Antigen Test Class II Microbiology 1 2024-03-22
PGI 1 2023-12-20
OEM 1 2023-03-10
OZE 1 2023-03-03
LQP Campylobacter Spp. Class I Microbiology 1 2021-11-23
Safety

Recalls (10)

Class I (serious)
1
Risk of injury / death
Total recalls
10
Currently ongoing
6
Most recent
2026-04-06
DateSeverityStatusRecall # ProductCodeReason
2026-04-06 Class II Ongoing Z-2169-2026 QuickVue Dipstick Strep A Test, 50T, REF 20108, antigens, all groups, streptococcus spp. Product has the potential for false positive results
2025-06-17 Class II Ongoing Z-2545-2025 QuickVue: Dipstick Strep A Test: 50T, REF: 20108; 25T, REF: 20125; 50T, SCN, REF: 20108SC Dipstick strep A test has potential for false positive results.
2024-03-05 Class II Ongoing Z-1637-2024 QUIDEL InflammaDry MMP-9 Test, REF: PRS-ID-20, 20 Tests There are two windows on the test device, the control line window and the test results window. The line for the test results window were misaligned. In instance…
2024-03-05 Class II Ongoing Z-1636-2024 QUIDEL InflammaDry MMP-9 Test, REF: PRS-ID-20-U, 20 Tests There are two windows on the test device, the control line window and the test results window. The line for the test results window were misaligned. In instance…
2024-01-03 Class II Ongoing Z-1086-2024 The Sofia 2 Flu + SARS Antigen FIA employs immunofluorescence technology in a sandwich design that is used with Sofia 2 … One lot of the Sofia 2 Flu + SARS Antigen FIA (Lot 709083) was labelled with incorrect expiration dates. The kits contain pouched cassettes labeled with an expi…
2023-02-01 Class II Ongoing Z-1308-2023 MicroVue C1-Inhibitor Plus EIA for measuring the amount of functional C1-lnhibitor protein in human plasma or serum, Cat… Kits with affected microtiter plates have the potential to produce low OD values, causing the run to fail, per the Validation requirements of the Package Insert…
2021-08-13 Class II Terminated Z-2477-2021 Lyra Direct SARS-CoV-2 Assay Emergency Use Authorization- Ref: M124. The Lyra Direct SARS-CoV-2 Assay is a real-time… Revised Instructions for Use: Potential for specimens from patients with high SARS-CoV-2 viral loads to be falsely interpreted as negative if target amplificati…
2021-04-27 Class I Terminated Z-1928-2021 Lyra SARS-CoV-2 Assay (M120) in vitro diagnostic test reagent In rare situations patients infected with high viral load of SARS CoV 2 may have samples that generate Ct values less than or equal to (d) 5 when certain amplif…
2020-09-25 Class II Terminated Z-0428-2021 QUIDEL Sofia SARS Antigen FIA IVD REF 20374 Due to false positive results.
2020-09-17 Class II Terminated Z-0124-2021 Sofia SARS Antigen FIA Package Insert The Sofia SARS Antigen FIA is a lateral flow immunofluorescent sandwich assay … Instructions for use in the package insert for SARS Antigen FIA test were updated to remove all references to a specific viral transport medium product as well …
Filings

All 510(k) clearances (7)

Date K-number Device Code Class Specialty
2024-03-22 K231795 QuickVue COVID-19 Test QYT Class II Microbiology
2023-12-20 K232286 Savanna HSV 1+2/VZV Assay, Savanna HSV 1+2/VZV Control Set, Savanna Instrument PGI
2023-12-13 K233688 Sofia 2 SARS Antigen+ FIA; Sofia 2 SARS Antigen+ FIA Control Swab Set QVF
2023-03-10 K230349 Lyra RSV+hMPV Assay OEM
2023-03-08 DEN220039 Sofia 2 SARS Antigen+ FIA, Sofia 2 SARS Antigen+ FIA Control Swab Set QVF
2023-03-03 K230236 Lyra Influenza A+B Assay OZE
2021-11-23 K211342 Sofia 2 Campylobacter FIA LQP Class I Microbiology