| 2025-04-16 |
Class II
|
Completed |
Z-1903-2025 |
VERIGENE Gram Negative Blood Culture (BC-GN) Nucleic Acid Test, REF 20-006-021; for use with the sample-to-results VERIG… |
— |
It was determined that the consumable issue may result in No Call - INT CTL 1 and/or False Negative results on a small portion of the lot of test cartridges. |
| 2024-06-20 |
Class II
|
Ongoing |
Z-2533-2024 |
Verigene Gram Positive Blood Culture (BC-GP) Nucleic Acid Test |
— |
Potential for defective test cartridges which may result in false positive results for the Staphylococcus lugdunensis and Enterococcus faecium targets. |
| 2023-11-07 |
Class II
|
Ongoing |
Z-0500-2024 |
Luminex VERIGENE BC-GP Utility Tray (5-Pack Carrier), Gram-Positive Blood Culture Nucleic Acid Test, REF 20-011-018, a c… |
— |
Potentially defective utility trays in the reagent kits. |
| 2023-06-05 |
Class II
|
Ongoing |
Z-2024-2023 |
VERIGENE Clostridium difficile Nucleic Acid Test, REF 30-002-022 |
— |
It is possible that in rare instances the VERIGENE CDF Nucleic Acid Test Kit (Part No. 20-005-022) and the VERIGENE Enteric Pathogens Nucleic Acid Test Kit (Par… |
| 2023-06-05 |
Class II
|
Ongoing |
Z-2023-2023 |
Verigene Enteric Pathogens Nucleic Acid Test (EP), REF 30-002-023 |
— |
It is possible that in rare instances the VERIGENE CDF Nucleic Acid Test Kit (Part No. 20-005-022) and the VERIGENE Enteric Pathogens Nucleic Acid Test Kit (Par… |
| 2022-09-14 |
Class II
|
Ongoing |
Z-0134-2023 |
ARIES SARS-CoV-2 Assay, REF: 50-10047 |
— |
A part defect with the wash 1 syringe of an SARS-CoV-2 assay could lead to incomplete extraction thereby producing an invalid or false negative assay result. |
| 2022-07-14 |
Class II
|
Ongoing |
Z-1524-2022 |
ARIES SARS-CoV-2 Assay |
— |
SARS-CoV-2 assay that detects SARS-CoV-2 ORF1ab and N genes may not detect the ORF1ab gene. A positive results if either SARS-CoV-2 genes is detected, but If bo… |
| 2022-06-17 |
Class II
|
Ongoing |
Z-1335-2022 |
VERIGENE Enteric Pathogens Nucleic Acid Test, Part No. 30-002-23 |
— |
There is a potential for false negative results using VERIGENE CDF Stool PREP KIT and VERIGENE EP Stool PREP KIT due to hydrophobic characteristics of the swab. |
| 2022-06-17 |
Class II
|
Ongoing |
Z-1334-2022 |
Verigene CDF Nucleic Acid Test, Part No. 30-002-22 |
— |
There is a potential for false negative results using VERIGENE CDF Stool PREP KIT and VERIGENE EP Stool PREP KIT due to hydrophobic characteristics of the swab. |
| 2022-04-05 |
Class II
|
Ongoing |
Z-1092-2022 |
Verigene Processor SP, Models 10-0000-07/10-0000-07R a component of the Verigene system |
— |
Heater within the Verigene System may be outside of established temperature limits for assays which could result in false negative results. |
| 2022-02-15 |
Class II
|
Ongoing |
Z-1109-2022 |
VERIGENE Nucleic Acid Test Kit-BC-GN Extraction Tray - 9.73 mL, REF 20-009-021 |
— |
Higher than normal "No Call Internal Control failures" due to a missing reagent within a small subset of the extraction tray lot. |
| 2021-11-17 |
Class II
|
Terminated |
Z-0553-2022 |
ARIES HSV 1&2 Assay, Catalog/REF# 50-10017 |
— |
Impacted lot may leak inside the ARIES instrument. Testing confirmed a leak rate of 0.9%. Leaking cassettes could potentially lead to incorrect results or a del… |
| 2021-08-03 |
Class II
|
Ongoing |
Z-2451-2021 |
Verigene EP Amplification Reagent Kit Test |
— |
There is potential for false positive results. |
| 2021-04-16 |
Class II
|
Terminated |
Z-0498-2022 |
ARIES HSV 1&2 Assay, Part Number/REF 50-10017 |
— |
Impacted lot may leak inside the ARIES instrument. |
| 2021-03-18 |
Class II
|
Ongoing |
Z-1488-2021 |
VERIGENE Processor SP - Product Usage: intended for processing and identifying nucleic acids utilizing gold nanoparticle… |
— |
Potential for a false-negative result for Vibrio parahaemolyticus, Salmonella, and/or Shigella spp when used with the VERIGENE Enteric Pathogens Nucleic Acid Te… |
| 2020-10-30 |
Class II
|
Ongoing |
Z-2011-2021 |
Verigene Gram Negative Blood Culture Nucleic Acid Test v2 (BC-GNv2) Model Number: 20-006-026 |
— |
Potential for a false-negative result. |
| 2020-10-30 |
Class II
|
Ongoing |
Z-2010-2021 |
Verigene Clostridium difficile Nucleic Acid Test Kit (CDF) Model Number: 20-006-022 |
— |
Potential for a false-negative result. |
| 2020-10-30 |
Class II
|
Ongoing |
Z-2009-2021 |
Verigene Enteric Pathogens Nucleic Acid Test (EP) Model Number: 20-006-023 |
— |
Potential for a false-negative result. |
| 2020-10-30 |
Class II
|
Ongoing |
Z-2008-2021 |
Verigene Gram Negative Blood Culture Nucleic Acid Test (BC-GN) Model Number: 20-006-021 |
— |
Potential for a false-negative result. |
| 2020-10-30 |
Class II
|
Ongoing |
Z-2007-2021 |
Verigene Gram-Positive Blood Culture Nucleic Acid Test (BC-GP) Model Number: 20-006-018 |
— |
Potential for a false-negative result. |
| 2020-10-30 |
Class II
|
Ongoing |
Z-2006-2021 |
Verigene Respiratory Pathogens Flex Nucleic Acid Test (RP Flex) Model Number: 20-006-024 |
— |
Potential for a false-negative result. |
| 2020-10-13 |
Class II
|
Terminated |
Z-0477-2021 |
Verigene Processor SP, Model Numbers 10-0000-07 and 10-0000-07R. Used with assay Luminex, VERIGENE Gram-Negative Blood … |
— |
Luminex has determined that three (3) separate test fixtures used by field service engineers to service the VERIGENE SP Processors were procured from unapproved… |
| 2020-10-13 |
Class II
|
Terminated |
Z-0476-2021 |
Verigene Processor SP, Model Numbers 10-0000-07 and 10-0000-07R. Used with assay: Luminex, VERIGENE Gram-Positive Blood… |
— |
Luminex has determined that three (3) separate test fixtures used by field service engineers to service the VERIGENE SP Processors were procured from unapproved… |
| 2020-06-15 |
Class II
|
Terminated |
Z-2776-2020 |
Verigene Processor SP with assay Luminex, VERIGENE Gram-Negative Blood Culture Nucleic Acid Test, BC-GN, IVD - Product U… |
— |
An instrument failure mode that may result in a Blood Culture Gram Positive (BC-GP) or Gram Negative (BC-GN) false negative call. |
| 2020-06-15 |
Class II
|
Terminated |
Z-2775-2020 |
Verigene Processor SP with assay: Luminex, VERIGENE Gram-Positive Blood Culture Nucleic Acid Test,BC-GP, IVD - Product U… |
— |
An instrument failure mode that may result in a Blood Culture Gram Positive (BC-GP) or Gram Negative (BC-GN) false negative call. |