| 2026-04-02 |
Class II
|
Ongoing |
Z-2046-2026 |
Brand Name: Da Vinci X and Da Vinci Xi Product Name: da Vinci X, Xi Surgical System Model/Catalog Number: IS4000; IS4… |
— |
Due to manipulator containing screws with in the arm sub-assembly that my be susceptible to breaking. |
| 2026-03-11 |
Class I
|
Ongoing |
Z-1855-2026 |
Intuitive 8 mm SureForm 30 Gray Reloads Reference Numbers: 48230M-05 and 48230M-06 |
— |
Reloads for curved-tipped stapler may potentially produce an incomplete staple line. |
| 2025-12-30 |
Class II
|
Ongoing |
Z-1355-2026 |
da Vinci 5 Surgeon Console Viewer Display, ASSY, DV5 CONSOLE, IS5000, Part Number: 380730-45 |
— |
Robotic-assisted surgical system has Viewer Display manufactured with outdated firmware, may result in loss of one display-loss of 3D surgical field (depth perc… |
| 2025-12-15 |
Class II
|
Ongoing |
Z-1096-2026 |
da Vinci SP, SP Access Port Kit, Large Incision Reference Numbers:430073 (2.7-4cm,SP1098, Box) & 430075 (2.7-7cm,SP1… |
— |
Access Port System tray may develop cracks potentially resulting in a sterility breach. |
| 2025-12-09 |
Class II
|
Ongoing |
Z-1701-2026 |
Brand Name: da Vinci S, Si Permanent Cautery Hook Instrument Product Name: da Vinci S, Si Permanent Cautery Hook Instru… |
— |
Due to increased in complaints regarding frayed or broken pitch cables on reusable surgical instruments |
| 2025-12-09 |
Class II
|
Ongoing |
Z-1700-2026 |
Brand Name: da Vinci S, Si Tenaculum Forceps Instrument Product Name: da Vinci S, Si Tenaculum Forceps Instrument Mode… |
— |
Due to increased in complaints regarding frayed or broken pitch cables on reusable surgical instruments |
| 2025-12-09 |
Class II
|
Ongoing |
Z-1699-2026 |
Brand Name: da Vinci S, Si Grasping Retractor Instrument Product Name: da Vinci S, Si Grasping Retractor Instrument Mo… |
— |
Due to increased complaints for broken/frayed grip cables for reusable instruments. |
| 2025-12-09 |
Class II
|
Ongoing |
Z-1698-2026 |
Brand Name: da Vinci S, Si Mega Needle Driver Instrument Product Name: da Vinci S, Si Mega Needle Driver Instrument Mo… |
— |
Due to increased complaints for broken/frayed grip cables for reusable instruments. |
| 2025-12-09 |
Class II
|
Ongoing |
Z-1697-2026 |
Brand Name: da Vinci S, Si Double Fenestrated Grasper Instrument Product Name: da Vinci S, Si Double Fenestrated Graspe… |
— |
Due to increased complaints for broken/frayed grip cables for reusable instruments. |
| 2025-12-09 |
Class II
|
Ongoing |
Z-1696-2026 |
Brand Name: da Vinci S, Si Monopolar Curved Scissors Instrument Product Name: da Vinci S and Si Monopolar Curved Scisso… |
— |
Due to increased complaints for broken/frayed grip cables for reusable instruments. |
| 2025-12-04 |
Class II
|
Ongoing |
Z-1134-2026 |
Brand Name: Ion Endoluminal System Product Name: Ion Vision Probe Bag Model/Catalog Number: 490127 Software Version: … |
— |
Due to probe bags that may have a compromised or incomplete sterile pouch seal. |
| 2025-11-17 |
Class II
|
Ongoing |
Z-1428-2026 |
Da Vinci 5 ASSY, DV5 CONSOLE, IS5000 Model/Catalog Number: 380730 Used for minimally invasive surgery. |
— |
An error event following the release of a software version for the surgical system that can result in loss of user interface content on an external monitor or t… |
| 2025-11-07 |
Class II
|
Ongoing |
Z-1232-2026 |
Brand Name: Da Vinci Product Name: da Vinci X, Xi Surgical System, & da Vinci 5 Surgical System Model/Catalog Number:… |
— |
Due to a software implementation error that allowed instruments arms failing an important diagnostic test to remain in clinical use. This test was supposed to b… |
| 2025-02-26 |
Class II
|
Ongoing |
Z-1325-2025 |
Brand Name: Da Vinci 5 Product Name: ASSY,DV5 CONSOLE,IS5000 Foot Tray Pedals Model/Catalog Number: 380730 Software V… |
— |
Due to an increase in complaints concerning foot tray pedal spring failing resulting in the pedal remaining pressed |
| 2024-12-19 |
Class II
|
Ongoing |
Z-0924-2025 |
8MM, Small Graptor REF 470318 Is a grasping retractor Instrument used with the da Vinci X/Xi Surgical Systems in a wi… |
— |
Due to an increase in complaints for pitch cable failures related to forceps and small Graptor instruments |
| 2024-12-19 |
Class II
|
Ongoing |
Z-0923-2025 |
8MM, Tenaculum Forceps REF 470207 Instrument used with the da Vinci X/Xi Surgical Systems in a wide variety of proced… |
— |
Due to an increase in complaints for pitch cable failures related to forceps and small Graptor instruments |
| 2024-12-19 |
Class II
|
Ongoing |
Z-0883-2025 |
8MM,FORCE BIPOLAR,IS4000 REF 471405 |
— |
Due to increased complaints regarding frayed or broken grip cables on reusable instruments with jaws. |
| 2024-12-19 |
Class II
|
Ongoing |
Z-0882-2025 |
8MM,LONG BIPOLAR GRASPER,IS4000 REF 471400 |
— |
Due to increased complaints regarding frayed or broken grip cables on reusable instruments with jaws. |
| 2024-12-19 |
Class II
|
Ongoing |
Z-0881-2025 |
8MM,CURVED BIPOLAR DISSECTOR,IS4000 REF 471344 |
— |
Due to increased complaints regarding frayed or broken grip cables on reusable instruments with jaws. |
| 2024-12-19 |
Class II
|
Ongoing |
Z-0880-2025 |
8MM,MEGA SUTURECUT ND,IS4000 REF 471309 |
— |
Due to increased complaints regarding frayed or broken grip cables on reusable instruments with jaws. |
| 2024-12-19 |
Class II
|
Ongoing |
Z-0879-2025 |
8MM,LARGE SUTURECUT NEEDLE DRIVER,IS4000 REF 471296 |
— |
Due to increased complaints regarding frayed or broken grip cables on reusable instruments with jaws. |
| 2024-12-19 |
Class II
|
Ongoing |
Z-0878-2025 |
8MM,FENESTRATED BIPOLAR FORCEPS,IS4000 REF 471205 |
— |
Due to increased complaints regarding frayed or broken grip cables on reusable instruments with jaws. |
| 2024-12-19 |
Class II
|
Ongoing |
Z-0877-2025 |
8MM,COBRA GRASPER,IS4000 REF 471190 |
— |
Due to increased complaints regarding frayed or broken grip cables on reusable instruments with jaws. |
| 2024-12-19 |
Class II
|
Ongoing |
Z-0876-2025 |
8MM,MARYLAND BIPOLAR FORCEPS,IS4000 REF 471172 |
— |
Due to increased complaints regarding frayed or broken grip cables on reusable instruments with jaws. |
| 2024-12-19 |
Class II
|
Ongoing |
Z-0875-2025 |
8MM,MICRO BIPOLAR FORCEPS,IS4000 REF 471171 |
— |
Due to increased complaints regarding frayed or broken grip cables on reusable instruments with jaws. |
| 2024-12-19 |
Class II
|
Ongoing |
Z-0874-2025 |
8MM,PROGRASP FORCEPS,IS4000 REF 471093 |
— |
Due to increased complaints regarding frayed or broken grip cables on reusable instruments with jaws. |
| 2024-12-19 |
Class II
|
Ongoing |
Z-0873-2025 |
8MM,CADIERE FORCEPS,IS4000 REF 471049 |
— |
Due to increased complaints regarding frayed or broken grip cables on reusable instruments with jaws. |
| 2024-12-19 |
Class II
|
Ongoing |
Z-0872-2025 |
8MM,LONG TIP FORCEPS,IS4000 REF 471048 |
— |
Due to increased complaints regarding frayed or broken grip cables on reusable instruments with jaws. |
| 2024-12-19 |
Class II
|
Ongoing |
Z-0871-2025 |
8MM,FORCE BIPOLAR,IS4000 REF 470405 |
— |
Due to increased complaints regarding frayed or broken grip cables on reusable instruments with jaws. |
| 2024-12-19 |
Class II
|
Ongoing |
Z-0870-2025 |
8MM,HORIZON SMALL CLIP APPLIER,IS4000¿ REF 470401 |
— |
Due to increased complaints regarding frayed or broken grip cables on reusable instruments with jaws. |
| 2024-12-19 |
Class II
|
Ongoing |
Z-0869-2025 |
8MM,TIP-UP FENESTRATED GRASPER,IS4000¿ REF 470347 |
— |
Due to increased complaints regarding frayed or broken grip cables on reusable instruments with jaws. |
| 2024-12-19 |
Class II
|
Ongoing |
Z-0868-2025 |
8MM,CURVED BIPOLAR DISSECTOR,IS4000¿ REF 470344 |
— |
Due to increased complaints regarding frayed or broken grip cables on reusable instruments with jaws. |
| 2024-12-19 |
Class II
|
Ongoing |
Z-0867-2025 |
8MM,MEDIUM-LARGE CLIP APPLIER,IS4000¿ REF 470327 |
— |
Due to increased complaints regarding frayed or broken grip cables on reusable instruments with jaws. |
| 2024-12-19 |
Class II
|
Ongoing |
Z-0866-2025 |
8MM,SMALL GRASPING RETRACTOR,IS4000¿ REF 470318 |
— |
Due to increased complaints regarding frayed or broken grip cables on reusable instruments with jaws. |
| 2024-12-19 |
Class II
|
Ongoing |
Z-0865-2025 |
8MM,MEGA SUTURECUT ND,IS4000¿ REF 470309 |
— |
Due to increased complaints regarding frayed or broken grip cables on reusable instruments with jaws. |
| 2024-12-19 |
Class II
|
Ongoing |
Z-0864-2025 |
8MM,LARGE SUTURECUT NEEDLE DRIVER,IS4000¿ REF 470296 |
— |
Due to increased complaints regarding frayed or broken grip cables on reusable instruments with jaws. |
| 2024-12-19 |
Class II
|
Ongoing |
Z-0863-2025 |
8MM,DUAL BLADE RETRACTOR,IS4000¿ REF 470249 |
— |
Due to increased complaints regarding frayed or broken grip cables on reusable instruments with jaws. |
| 2024-12-19 |
Class II
|
Ongoing |
Z-0862-2025 |
8MM,ATRIAL RETRACTOR SHORT RIGHT,IS4000¿ REF 470246 |
— |
Due to increased complaints regarding frayed or broken grip cables on reusable instruments with jaws. |
| 2024-12-19 |
Class II
|
Ongoing |
Z-0861-2025 |
8MM,LARGE HEM-O-LOK CLIP APPLIER,IS4000¿ REF 470230 |
— |
Due to increased complaints regarding frayed or broken grip cables on reusable instruments with jaws. |
| 2024-12-19 |
Class II
|
Ongoing |
Z-0860-2025 |
8MM,TENACULUM FORCEPS,IS4000¿ REF 470207 |
— |
Due to increased complaints regarding frayed or broken grip cables on reusable instruments with jaws. |
| 2024-12-19 |
Class II
|
Ongoing |
Z-0859-2025 |
8MM,FENESTRATED BIPOLAR FORCEPS,IS4000¿ REF 470205 |
— |
Due to increased complaints regarding frayed or broken grip cables on reusable instruments with jaws. |
| 2024-12-19 |
Class II
|
Ongoing |
Z-0858-2025 |
8MM,MEGA NEEDLE DRIVER,IS4000¿ REF 470194 |
— |
Due to increased complaints regarding frayed or broken grip cables on reusable instruments with jaws. |
| 2024-12-19 |
Class II
|
Ongoing |
Z-0857-2025 |
8MM,RESANO FORCEPS,IS4000 ¿ REF 470181 |
— |
Due to increased complaints regarding frayed or broken grip cables on reusable instruments with jaws. |
| 2024-12-19 |
Class II
|
Ongoing |
Z-0856-2025 |
8MM,MARYLAND BIPOLAR FORCEPS,IS4000 ¿ REF 470172 |
— |
Due to increased complaints regarding frayed or broken grip cables on reusable instruments with jaws. |
| 2024-12-19 |
Class II
|
Ongoing |
Z-0855-2025 |
8MM,MICRO BIPOLAR FORCEPS,IS4000 ¿ REF 470171 |
— |
Due to increased complaints regarding frayed or broken grip cables on reusable instruments with jaws. |
| 2024-12-19 |
Class II
|
Ongoing |
Z-0854-2025 |
8MM,PROGRASP FORCEPS,IS4000 ¿ REF 470093 |
— |
Due to increased complaints regarding frayed or broken grip cables on reusable instruments with jaws. |
| 2024-12-19 |
Class II
|
Ongoing |
Z-0853-2025 |
8MM,CADIERE FORCEPS,IS4000 ¿ REF 470049 |
— |
Due to increased complaints regarding frayed or broken grip cables on reusable instruments with jaws. |
| 2024-12-19 |
Class II
|
Ongoing |
Z-0852-2025 |
8MM,DEBAKEY FORCEPS,IS4000 ¿ REF 470036 |
— |
Due to increased complaints regarding frayed or broken grip cables on reusable instruments with jaws. |
| 2024-12-19 |
Class II
|
Ongoing |
Z-0851-2025 |
8MM,BLACK DIAMOND MICRO FORCEPS,IS4000 ¿ REF 470033 |
— |
Due to increased complaints regarding frayed or broken grip cables on reusable instruments with jaws. |
| 2024-12-19 |
Class II
|
Ongoing |
Z-0850-2025 |
8MM, ROUND TIP SCISSORS, IS4000 ¿ REF 470007 |
— |
Due to increased complaints regarding frayed or broken grip cables on reusable instruments with jaws. |
| 2024-12-19 |
Class II
|
Ongoing |
Z-0849-2025 |
8MM, LARGE NEEDLE DRIVER, IS4000 REF 470006 |
— |
Due to increased complaints regarding frayed or broken grip cables on reusable instruments with jaws. |
| 2024-12-19 |
Class II
|
Ongoing |
Z-0848-2025 |
8MM, POTTS SCISSORS, IS4000 REF 470001 |
— |
Due to increased complaints regarding frayed or broken grip cables on reusable instruments with jaws. |
| 2024-12-19 |
Class II
|
Ongoing |
Z-0847-2025 |
8MM, MONOPOLAR CURVED SCISSORS, IS4000 REF 470179 |
— |
Due to increased complaints regarding frayed or broken grip cables on reusable instruments with jaws. |
| 2024-08-21 |
Class II
|
Ongoing |
Z-0964-2026 |
da Vinci 5, Surgeon Console Column Motor Connector; ASSY,DV5 CONSOLE,SSC,IS5000; Part Number: 380730-40 |
— |
Surgical system Error 23062 due to connector1) Partially damaged "Potential problem with ergonomics: Disable - Retry " or 2) Failed "Disable Ergonomics: Viewer,… |
| 2024-07-12 |
Class II
|
Ongoing |
Z-2720-2024 |
Ion Endoluminal System, REF: 380748-65 |
— |
There is a potential that the robotic system's instrument cart arm may contain screws that may potentially fail which could result in uncontrolled motion of a… |
| 2024-03-13 |
Class II
|
Ongoing |
Z-1518-2024 |
Patient Cart, Part: 380601, a component of the da Vinci SP Surgical System, Model: SP1098 |
— |
Surgical system may have inadequately welded top and/or bottom belts in the link 2 of the entry guide manipulator assembly/instrument arm joints, that may cause… |
| 2023-10-06 |
Class II
|
Ongoing |
Z-0406-2024 |
Da Vinci Single-Site Wristed Needle Driver, REF: 478115, 5 mm |
— |
There is the potential for the needle drive to become dislodged and/or broken which could result in uncontrollable movement. |
| 2023-06-12 |
Class II
|
Ongoing |
Z-2059-2023 |
da Vinci Xi/X Tip-Up Fenestrated Grasper, REF: 470347, VER: 12 |
— |
Fenestrated Graspers have a manufacturing issue has the potential to cause breakage on both upper and/or lower grips, which could lead to stainless steel fragme… |
| 2023-02-10 |
Class II
|
Ongoing |
Z-1293-2023 |
da Vinci Xi Surgical System Model IS4000 da Vinci X Surgical System Model IS4200 |
— |
Due to Universal Surgical Manipulator (USM) instrument carriage being loose as a result of the linear rail component not being manufactured within specification… |
| 2023-01-24 |
Class II
|
Ongoing |
Z-1262-2023 |
Patient Side Cart, REF: 380620, with instrument arms, used as part of the da Vinci X Surgical System, REF: IS4200; Pa… |
— |
Preventative maintenance data was used to identify instrument Arms, part of surgical systems, that allow surgeons to perform surgical tasks, that may be at risk… |
| 2022-10-07 |
Class II
|
Ongoing |
Z-0340-2023 |
INTUITIVE Da Vinci Xi 8mm SureForm 30 Curved-Tip Stapler Da Vinci Xi|X REF 488530 INTUITIVE Da Vinci 8mm SureForm 30 … |
— |
Potential staple deployment failure and device fragment generation |
| 2022-09-20 |
Class II
|
Ongoing |
Z-0133-2023 |
da Vinci X (IS4200) and Xi (IS4000) systems, which consists of finished devices Surgeon Console (SSC), Patient Cart (PSC… |
— |
Inadvertent energy delivery from surgical system instrument if 1) Force bipolar and bipolar instruments installed on system 2) Force bipolar connected to Force … |
| 2022-07-01 |
Class II
|
Ongoing |
Z-1460-2022 |
Da Vinci X/Xi Large Clip Applier, Model 470230 Da Vinci X/Xi Medium-Large Clip Applier, Model 470327 Da Vinci X/Xi Sma… |
— |
Due to the potential for unexpected motion caused by the partial disengagement of the instrument from the system. |
| 2022-07-01 |
Class II
|
Ongoing |
Z-1459-2022 |
Da Vinci S/Si Large Clip Applier, Model 420230 Da Vinci S/Si Medium-Large Clip Applier, Model 420327 Da Vinci S/Si Sma… |
— |
Due to the potential for unexpected motion caused by the partial disengagement of the instrument from the system. |
| 2022-06-22 |
Class II
|
Ongoing |
Z-1484-2022 |
The E-100 Generator (PN 374848-09) is a bipolar electrosurgical unit (ESU) designed to be used with the da Vinci Xi and … |
— |
Due to preventative maintenance (PM) not being performed on E-100 generators which is a bipolar electrosugical unit designed to be used with the da Vinci Xi and… |
| 2022-03-17 |
Class II
|
Ongoing |
Z-0999-2022 |
da Vinici X da Vinci Xi Sureform 45 REF 480445 da Vinci X da Vinci Xi Sureform 45 Curved-Tip REF 480545 da Vinic… |
— |
As a result of complaint data review, it identified tissue pushout events occurring during firing of the SureForm stapler when tissue is pushed distally within … |
| 2022-03-03 |
Class II
|
Ongoing |
Z-1210-2022 |
DAVINCI | Energy SynchroSeal da Vinci X' da Vinci Xi', Single Use Instrument 8mm, REF 480440 |
— |
Placing excessive tissue in the instrument jaws of the devices prior to sealing and transection can result in an insufficient seal. |
| 2022-03-03 |
Class II
|
Ongoing |
Z-1209-2022 |
VESSEL SEALER EXTEND, Single-Use Instrument EndoWrist Instruments 8mm, da Vinci X' da Vinci Xi', REF 480422 |
— |
Placing excessive tissue in the instrument jaws of the devices prior to sealing and transection can result in an insufficient seal. |
| 2021-12-23 |
Class II
|
Ongoing |
Z-0702-2022 |
da Vinci Xi and X 12-8 mm Conductive Cannula Reducer, REF: 470381-11 |
— |
Conductive Cannula Reducer metal tip may get dislodged from the plastic shaft. If unnoticed, additional surgery may be required to remove the metal tip. If the … |
| 2021-09-22 |
Class II
|
Ongoing |
Z-0419-2022 |
da Vinci SP Surgical systems with the following Model Name/ Model Number / UDI: ASSY,PSS,SP1098,P4/ 380601-44/ 00886874… |
— |
Issue was identified during internal engineering evaluation. Use of the system with the affected software version may experience either an inability to deliver … |
| 2021-09-21 |
Class II
|
Terminated |
Z-0275-2022 |
The da Vinci Xi and X surgical systems (IS4000 and IS4200) each consist of three main components: the Surgeon Console (S… |
— |
Incorrect expiration date on its package labeling (shipper box and inner carton label). |
| 2021-08-06 |
Class II
|
Terminated |
Z-0106-2022 |
Ion Flexison Biopsy Needle, 19G, Extension Range : 0-3 cm, Ref: 490104-09 and 49004-10, 5-pack, Sterile EO, Rx only, UDI… |
— |
Potential for the sheath tip on the biopsy needle to separate from the sheath shaft. |
| 2020-10-23 |
Class II
|
Terminated |
Z-0489-2021 |
Box Label: ION Fully Articulating Catheter, REF 490105, VER 08 - Product Usage: used to navigate the Ion Fully Articulat… |
— |
The distal tip ring of the fully articulating catheter may become dislodged during the procedure. |
| 2020-06-10 |
Class II
|
Ongoing |
Z-2950-2020 |
ION Reprocessing Accessories Kit, IF1000 (Part Number: 490024-03) UDI:00886874119129. The kit includes an ION Catheter R… |
— |
One type of the ION Catheter Reprocessing Covers (PN 490114-02) has the potential to become disengaged or incorrectly engaged to the ION Fully Articulating Cath… |
| 2020-06-10 |
Class II
|
Ongoing |
Z-2949-2020 |
Ion Catheter Reprocessing Cover, IF1000 (Part Number:490114-02) UDI:00886874116845. |
— |
One type of the ION Catheter Reprocessing Covers (PN 490114-02) has the potential to become disengaged or incorrectly engaged to the ION Fully Articulating Cath… |