Hamilton Medical AG

Bonaduz, CH · 3 510(k) clearances · 19 recalls (15 Class I)

Total clearances
3
2020-05-04 → 2021-02-05
Last 12 months
0
Product codes
1
Most recent
2021-02-05
Trend

Clearance cadence by quarter

Portfolio

Product codes worked

Code Device name Class Specialty Clearances Most recent
CBK 3 2021-02-05
Safety

Recalls (19)

Class I (serious)
15
Risk of injury / death
Total recalls
19
Currently ongoing
18
Most recent
2026-05-29
DateSeverityStatusRecall # ProductCodeReason
2026-05-29 Class I Ongoing Z-2463-2026 Breathing circuit set, coaxial: REF: 260127, 260128, 260167, 260168 used with HAMILTON-C1, HAMILTON-T1 and HAMILTON-MR1 … Ventilator coaxial breathing circuit may have, expiratory valve sets with membranes sticking to valve body, not detectable during pre-operative test, which will…
2026-05-22 Class II Ongoing Z-2625-2026 IntelliCuff, Portable automatic cuff pressure controller REF: 951001 Due to reported complaints, the cuff device may alarm with a "Cuff System Leakage" error. As a result, the motor may pump continuously and fail to maintain the …
2025-06-26 Class I Ongoing Z-2167-2025 Breathing circuit set, coaxial, 1.80 m, with flow sensor and expiratory valve set, REF: 260128, used with HAMILTON-C1, H… Ventilator coaxial breathing circuit may have a crack in blue tubing, which is used to deliver fresh gas to the patient. The crack will compromise inspiratory a…
2025-06-03 Class I Ongoing Z-2328-2025 Hamilton C6 REF 160021 (ESM Board PN 10144626 UDI-DI code: 76300028PN160021ZW Hamilton C6 is a ventilator intended t… A mechanical defect on a printed circuit board (PCB) as a result of PCB separating process. This defect might cause the ventilator to either fail at startup (n…
2024-05-15 Class I Ongoing Z-2020-2024 Ventilator HAMILTON-C6, PN: 160021 Ventilator may enter sensor fail mode, ventilation may not re-initiate, after patient is reconnected, which may cause hypoxia, if this sequence occurs: 1)User p…
2023-07-26 Class I Ongoing Z-2530-2023 Hamilton-T1, REF: MSP161339/02, ESM Shielding Set, Spare Part for ventilator Degrading capacitors on the control board of ventilators and spare parts may leak electrolyte onto the control board causing a short circuit on the board and/or…
2023-07-26 Class I Ongoing Z-2529-2023 Hamilton C1/T1/MR1, REF: MSP161502/12, Control Board Spare part for ventilator Degrading capacitors on the control board of ventilators and spare parts may leak electrolyte onto the control board causing a short circuit on the board and/or…
2023-07-26 Class I Ongoing Z-2528-2023 Hamilton-MR1, REF: 161010, Intensive Care Ventilator Degrading capacitors on the control board of ventilators and spare parts may leak electrolyte onto the control board causing a short circuit on the board and/or…
2023-07-26 Class I Ongoing Z-2527-2023 Hamilton-T1, REF: 161009, Intensive Care and Transport Ventilator Degrading capacitors on the control board of ventilators and spare parts may leak electrolyte onto the control board causing a short circuit on the board and/or…
2023-07-26 Class I Ongoing Z-2526-2023 Hamilton-T1, REF: 161006, Intensive Care and Transport Ventilator Degrading capacitors on the control board of ventilators and spare parts may leak electrolyte onto the control board causing a short circuit on the board and/or…
2023-07-26 Class I Ongoing Z-2525-2023 Hamilton-C1, REF: 161001, Portable Intensive Care Ventilator Degrading capacitors on the control board of ventilators and spare parts may leak electrolyte onto the control board causing a short circuit on the board and/or…
2023-06-15 Class I Ongoing Z-2142-2023 HAMILTON C3 Ventilator REF 160005 Is intended to provide positive pressure ventilatory support to adults and pediatr… Due to a software anomaly after approximately 91 days of cumulative use, the ventilator may stop and enter the ambient mode without prior notice.
2023-06-15 Class I Ongoing Z-2141-2023 HAMILTON C2 Ventilator Is intended to provide positive pressure ventilatory support to adults and pediatrics, and opt… Due to a software anomaly after approximately 91 days of cumulative use, the ventilator may stop and enter the ambient mode without prior notice.
2023-06-15 Class I Ongoing Z-2140-2023 HAMILTON T1 Ventilator REF 161006 1610060 161009 1610090 Is intended to provide positive pressure ventilatory sup… Due to a software anomaly after approximately 91 days of cumulative use, the ventilator may stop and enter the ambient mode without prior notice.
2023-06-15 Class I Ongoing Z-2139-2023 HAMILTON C1 Ventilator REF 161001 1610010 Is intended to provide positive pressure ventilatory support to adults a… Due to a software anomaly after approximately 91 days of cumulative use, the ventilator may stop and enter the ambient mode without prior notice.
2023-03-14 Class II Ongoing Z-1429-2023 HAMILTON-C6, REF: 160021 Software error causes, safety ventilation, in which ventilation continues in the "safety ventilation" mode with audible/visible alarm - patient inputs are not m…
2022-09-22 Class II Ongoing Z-0267-2023 Hamilton-C6 Due to a malfunction related to the backlight on the ventilator screen. The screen goes black for approximately 2-3 seconds, but it brightens up again when the …
2022-06-27 Class I Ongoing Z-1525-2022 HAMILTON-C6 Intensive Care Ventilator, REF: 160021 Ventilator status indicator board can become loose, which could lead to water ingress (disinfectants) that may lead to technical fault alarms. Multiple technica…
2021-01-05 Class III Completed Z-1385-2022 HAMILTON-H900 Humidifier, Models: 950001, 950004 When starting a humidifier, intended for respiratory gas conditioning during invasive and noninvasive mechanical ventilation, with an empty chamber, and water i…
Filings

All 510(k) clearances (3)

Date K-number Device Code Class Specialty
2021-02-05 K201306 HAMILTON-C3 CBK
2020-12-11 K201658 Hamilton-C6 CBK
2020-05-04 K193228 Hamilton-G5 CBK